Fixed infrared line cameras PYROLINE protection – robust and precise

The fixed infrared line cameras PYROLINE protection have robust stainless steel industry protection housing with the protection clas IP65. They are suitable for continuous industrial operation in rough environment. The infrared cameras can be optimally adjusted to different application. Quality management and process automation, as well as research and development and traffic control are exemplary for application areas.

Infrared line camera line scanner PYROLINE protection

What characterizes the infrared cameras of the series PYROLINE protection?

  • Measurement of temperature profiles between 0 °C and 3000 °C
  • Measurement at a short wavelength to minimize temperature measurement errors resulting from emissivity inaccuracies
  • Robust stainless steel industrial housing with protection class IP65
  • Equipped with water cooling for high ambient temperatures up to 150 °C
  • Air purge unit and protection window make the camera dust-protected
  • Numerous standard, wide angle and tele photo infrared lenses with motor focus (no moving outer parts) with an aperture angle up to 90°
  • Models with 128, 256 and 512 measurement points per line (128, 256 or 512 pixels respectively)
  • Response time 8 ms, 4 ms or 1 ms (2/measurement frequency)
  • Measurement frequency 256 lines per second, optional 512 lines per second, or 2000 lines per second
  • Fast data acquisition in real-time via Fast Ethernet without loss and with no appreciable time delay
  • Alarm and threshold monitoring as well as triggered measurements via two galvanically isolated inputs (trigger) and outputs (alarm)
  • Option of stand-alone operation without computer connection
  • Extensive standard software and application specific software solutions
  • Spectral range optimally adjustable to the application, for example 8 µm to 14 µm (measurement on nonmetals, coated metals, building materials), 3 µm to 5 µm (measurement on metals and ceramic), 4.8 µm to 5.2 µm (measurement on glass surfaces) or 0.8 µm to 1.1 µm (measurement on metals)

Everything at a glance:Overview broschure infrared line cameras PYROLINE

Models with 128 pixelsTemperature rangeSpectral rangeMeasurement frequencyAperture angle
PYROLINE 128LS/256 Hz protection0 °C to 80 °C8 µm to 14 µm256 lines per second40°, 60°, 90°
PYROLINE 128LS/512 Hz protection50 °C to 550 °C8 µm to 14 µm512 lines per second40°, 60°, 90°
PYROLINE 128L/256 Hz protection50 °C to 550 °C8 µm to 14 µm256 lines per second40°, 60°, 90°
PYROLINE 128MS/256 Hz protection200 °C to 800 °C3 µm to 5 µm256 lines per second40°, 60°, 90°
PYROLINE 128M/256 Hz protection450 °C to 1250 °C3 µm to 5 µm256 lines per second40°, 60°, 90°
PYROLINE 128GS/256 Hz protection250 °C to 800 °C4.8 µm to 5.2 µm256 lines per second40°, 60°, 90°
PYROLINE 128G/256 Hz protection450 °C to 1250 °C4.8 µm to 5.2 µm256 lines per second40°, 60°, 90°
Models with 256 pixelsTemperature rangeSpectral rangeMeasurement frequencyAperture angle
PYROLINE 256L/256 Hz protection50 °C to 550 °C8 µm to 14 µm256 lines per second40°, 60°, 90°
PYROLINE 256L/512 Hz protection150 °C to 800 °C8 µm to 14 µm512 lines per second40°, 60°, 90°
PYROLINE 256M/256 Hz protection450 °C to 1250 °C3 µm to 5 µm256 lines per second40°, 60°, 90°
PYROLINE 256G/256 Hz protection450 °C to 1250 °C4.8 µm to 5.2 µm256 lines per second40°, 60°, 90°
Models with 512 pixelsMeasuring temperature rangeSpectral rangeMeasurement frequencyAperture angle
PYROLINE 512N/256 Hz protection600 °C to 1500 °C,
optional: 1400 °C to 3000 °C
0.8 µm to 1.1 µm256 lines per second9°, 13°, 19°, 36°, 51°, 90°
PYROLINE HS 512N/2000 Hz protection650 °C to 1500 °C,
optional 1400 °C to 3000 °C
0.8 µm to 1.1 µm2000 lines per second9°, 13°, 19°, 36°, 51°, 90°